Voltammetry (BASI)

Voltammetry (BASI)

Previous page

ACCESSORIES FOR

Epsilon EClipse™ Electrochemical Analyzer

QVEF1031
Epsilon EClipse™ Electrochemical Analyzer


Product number     QVEF1031
OEM reference     EF-1031

The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry.

Features:
  • Potentiostat/Galvanostat
  • Bipotentiostat
  • Control BASi cell stands
  • Easy access front connector location for all electrochemical cell and cell stands
  • Positive feedback iR compensation
  • Internal dummy cells for hardware test
  • Analog filtering and digital smoothing


Accessories:
  • Compatible Cell stands:
    QVEF1085 - C-3 Cell Stand Package
    QVEF1100 - RDE-2 Rotating Disk Electrode
    QVEF1400 - Controlled Growth Mercury Electrode Cell Stand

  • Additional software
    QVEF1646 - Basic plus software
    QVEF1663 - DigiSim - Simulation Software for ElectroChemistry

  • Replacement cables:
    QVER9860 - Epsilon EClipse™ Bi-Potentiostat cable
    QVER9861 - Epsilon EClipse™ Cell Lead Cable
    QVER9862 - Epsilon EClipse™ Cell Stand Cable
    QVER9863 - Epsilon Eclipse™ Cell Lead Cable for Screen Printed Electrodes
Potentiostat:
  • Channel 1 applied potential: Dynamic DAC: 16 bit, ±3.275 V @ 0.1 mV resolution or ±10 V @ 0.33 mV resolution
  • Offset DAC: 8 bit, ±2.55 V @ 10 mV resolution
  • Channel 2 applied potential: Dynamic DAC: 8 bit, ±2.55 V @ 10 mV resolution
  • Compliance voltage: ±12 V
  • Maximum current: 100 mA
  • Bandwidth: > 100 kHz
  • Bias current: < 1pA
  • Electrometer input impedance: > 1012W
  • (values for parameters other than applied potential are for both channels)
Current-to-voltage converter:
  • Full scale sensitivity: 1 nA*, 10 nA*, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA,100 mA, (*secondary gain used)
  • Secondary gain: x1, x10, and x100
  • ADC resolution: 16 bit
  • Sampling rate: 50 kHz (20 µs/conversion)
  • Data length: up to 64k points - fast
Galvanostat:
  • Applied current: 50 pA - 50 mA
  • Range: ±10 V, ± 1 V
  • Measured potential resolution: 0.02 mV
  • Max leakage current: 30 pA
I/O:
  • Eout (applied potential)
  • Iout (current to voltage output)
  • Ein (input connection for external applied wave form)
  • Cell Stand port (control of C-3 Cell Stand and CGME)
  • Ordering Port (control of RDE-2)
  • PC (USB) port
  • Trigger out (TTL)
Minimum PC requirements:
  • Win 7 or higher
  • Pentium III
  • 512 MB RAM
  • 50 MB hard drive space available
  • USB port
Power requirements & Dimensions:
  • 120 or 240 VAC, 50/60 Hz, 60 VA
  • 15.75" (40 cm) x 5.25" (13 cm) x 12.75" (32.5 cm)
  • 17.5 lb (7.4 kg) (1 channel)
We use cookies on our website for technical and analytical reasons. Continue if you agree.